Anesthesia Machine MD-AM-1000

Anesthesia Machine MD-AM-1000

$8,148

Anesthesia Machine MD-AM-1000 operates on a gas source of O2 and N2O, with a pressure range of 280 kPa to 600 kPa. It has multiple ventilation modes, including IPPV, A/C, SIMV, SIGH, and MANUAL. It offers versatile working modes such as volume control and pressure limit, which adjust according to the patient's condition. The machine supports both adult and pediatric patients. Our Anesthesia Machine features various alarms and monitoring capabilities, to ensure patient safety.

Ventilation Mode IPPV, A/C, SIMV, SIGH, MANUAL
Ventilator Flowmeter O₂ (0.1 to 10 L/min) N₂O (0.1 to 10 L/min)
Ventilator Rapid Oxygen Supply 25 L/min to 75 L/min
Ventilator Tidal Volume 0.20 mL to 1500 mL
Ventilator Frequency 1/min to 100/min
Ventilator Pressure triggering Sensitivity -20 cm H₂O to 0 cm H₂O (Based on PEEP)
Ventilator PEEP 0 cm H₂O to 30 cm H₂O
Ventilator Flow Trigger Sensitivity 0.5 L/min to 30 L/min
Ventilator SIGH 0 (off) 1/100 to 5/100
Ventilator Apnea Ventilation OFF, 5sec to 60 sec
Ventilator Pressure Limit 20 cm H₂O to 100 cm H₂0
Monitoring Frequency 0 /min to 100 /min
Monitoring Volume 0 mL to 2000 mL
Monitoring MV 0 L/min to 100 L/min
Monitoring Oxygen Concentration 15% to 100%
AC power failure Alarm Power failure or no connection
Low Voltage alarm for backup battery < 11.3 ± 0.3 V
Volume (Tidal) Alarm ≤ 5 mL within 6s
Oxygen Concentration Alarm 19% to 100% (HIGH) 18% to 99 % (LOW)
Airway Pressure Alarm 20 cm H₂O to 100 cm H₂O (HIGH) 0 cm H₂O to 20 cm H₂O (LOW)
Minute Volume Alarm Adult (5 L/min to 20 L/min) Child (1 L/min to 15 L/min) (HIGH); 0 to 10 L/min (LOW)
Continuous Pressure Alarm (PEEP + 1.5 kPa) over 16s
Suffocation Warning 5s to 60s no spontaneous ventilation
Maximum Limited Pressure < 12.5 kPa
Fan Error Show On Screen
Oxygen Deficit Show On Screen
Gas Source O₂, N₂O
Pressure 280 kPa to 600 kPa
Power Supply 100V to 240 V
Dimensions (L × W × H) 740 × 800 × 1460 mm
Net Weight 66 Kg
Gross Weight 98 Kg
    • 7-inch TFT LCD screen display

    • Anesthesia Circuit Gas Outlet (ACGO) feature

    • Oxygen flush technique

    • High-precision flowmeter

    • 4-tube mechanical flowmeters

    • Multiple working modes

    • Alarms for power, voltage, volume, and pressure

  • Our Anesthesia Machine is used in the ICU and operating room to deliver general anesthesia to patients undergoing surgeries or medical procedures.