Anesthesia System MD-ANS-1001 provides a Positive End Expiratory Pressure range of 0 to 30 cmH2O. It provides a versatile ventilation parameter range of tidal volumes from 20 mL to 1500 mL. This advanced system offers a variety of ventilation modes and adjustable parameters. It also provides a wide frequency range ensuring precise control and customized care to meet the needs of each patient. Our anesthesia system is a highly efficient and adaptable solution ideal for anesthesia and critical care settings.
Features:
Oxygen sensor
Versatile Ventilation Modes
7-inch LED display
ACGO and Fast Oxygen supply
Precise Control of Respiratory Parameters
Advanced Alarm System
Comprehensive Monitoring
Oscillogram Display
Built-in backup battery
2-3 hours backup battery
Emergency and revival after operation
Compact and Durable Design
Standard accessories:
Anesthetic breathing system × 1
Power cord × 1
Fuse × 8
Fuse × 1
Fuse × 2
O2 cell × 1
CO2 sensor
Breathing tube × 2
Breathing tube × 2
Y connector Adult × 1
Y connector Child × 1
L connector × 2
Reservoir bag 1L × 1
Reservoir bag 3L × 1
Anesthetic mask adult × 1
Anesthetic mask infant × 1
Anesthesia Vaporizer × 2
High pressure O2 hose × 1
High-pressure AIR hose × 1
High pressure N2O hose × 1
Optional accessories:
Mainstream CO2 Sensor × 1
Sidestream CO2 Module × 1
Mainstream gas Analyzers × 1
Sidestream gas Analyzers × 1
CO2 Mainstream Module × 1
CO2 Sidestream Module × 1
Multi-gas Sensor × 1
Transfer and receiving system of exhaust gas × 1
Applications:
Anesthesia System MD-ANS-1001 is ideal for patients who require ventilatory support, including those experiencing respiratory failure, trauma, or undergoing emergency surgeries.
Specifications:
Ventilation Modes | IPPV, A/C, SIMV, SIGH, MANUAL |
---|---|
Gas Source | O2, N2O, AIR |
Flowmeter range | O2: 0.1 to 10 L/min; N2O: 0.1 to 10 L/min AIR: 0.1 to 10L/min |
Rapid Oxygen Supply Range | 25 L/min to 75 L/min |
Oxygen Concentration | 15 % to 100 % |
Tidal Volume (Vt) range | 0, 20 mL to 1500 mL |
Frequency range | 1 /min to 100 /min |
Inspiratory Ratio (I.E) | 2:1 - 1:6 |
Minute Volume (MV) | 0 L/min to 100 L/min |
Positive End-Expiratory Pressure (PEEP) | 0 cmH2O to 30 cmH2O |
Pressure Triggering Sensitivity (PTr) | -20 cmH2O to 20 cmH2O (Based on PEEP) |
Flow Trigger Sensitivity (FTr) | 0.5 L/min to 30 L/min |
SIGH | 0 (off) 1/100 to 5/100 |
Apnea Ventilation | OFF, 5 s to 60 s |
Gas Pressure Range | 280 kPa to 600 kPa |
Pressure Limit | 20 cmH2O to 100 cmH2O |
Bellow | 1.5L |
Oscillogram Types | P-T (Pressure-Time), F-T (Flow-Time), P-V loop (Pressure-Volume Loop) |
The AC power failure alarm | Power failure or no connection |
Alarm for backup battery | < 11.3 ± 0.3 V |
No tidal volume | ≤ 5 mL within 6 s |
High oxygen concentration alarm | 19% to 100% |
Low oxygen concentration alarm | 18% to 99% |
High airway pressure alarm | 20 cmH2O to 100 cmH2O |
Low airway pressure alarm | 0 cmH2O to 20 cmH2O |
High-minute volume alarm | Adult (5 L/min - 20 L/min) |
Low-minute volume alarm | Paed (1 L/min - 15 L/min, 0 - 10 L/min) |
Continuous pressure alarm | (PEEP+1.5 kPa) over 16s |
Suffocation warning | 5 s – 60 s no spontaneous ventilation |
The maximum limited pressure | < 12.5 kPa |
Fan error | Shows on screen |
Oxygen deficit | Shows on screen |
Display | 7-inch LED screen |
Power Consumption | 40 VA |
Power Supply | Voltage: 100 to 240 V Power Frequency: 50/60 Hz |
Packing Dimension | 760 × 970 × 1550 mm |
Net Weight | 82.5 kg |
Gross Weight | 143 kg |