Download Catalog For :

Anesthesia System MD-ANS-1006

Anesthesia System MD-ANS-1006

Anesthesia System MD-ANS-1006 offers precise gas flow rates for O2, N2O, and air. It ranges from 0.2–15 L/min for O2 and air, 0.2–12 L/min for N2O. Advanced Oscillogram Monitoring tracks critical respiratory parameters. The alarms for battery status, low oxygen supply, and fan errors ensure uninterrupted power. It features adjustable tidal volume (10–1500 mL) and frequency (1–100 breaths/min) for customized ventilation strategies.  Our system ensures enhanced safety and flexibility ideal for anesthesia and critical care settings.

Features:

  • Patient Centered Ventilation

  • customizable ventilator parameters

  • Controlled and spontaneous breathing support.

  • apnea and suffocation alerts.

  • Advanced Oscillogram Monitoring

  • Features Real-time monitoring

  • 15” TFT LCD touchscreen

  • Pressure and Flow Controls

  • Automatic decompression to ensure safety.

  • LED top light

  • Battery Backup

  • Packed in Compact wooden case

Standard accessories:

  • Anesthetic breathing system × 1

  • Power cord 4m × 1

  • Fuse × 8

  • Fuse × 1

  • O2 cell × 1

  • Adult Anesthesia Breathing Circuit(reusable) × 2

  • Child Anesthesia Breathing Circuit(reusable) × 2

  • Breathing tube × 1

  • Y connector × 1

  • Y connector × 1

  • L connector × 2

  • Straight connector × 1

  • Reservoir bag 1L × 1

  • Reservoir bag 3L × 1

  • Anesthetic mask adult × 1

  • Anesthetic mask infant × 1

  • Vaporizer × 2

  • High pressure O2 hose × 1

  • High-pressure AIR hose × 1

Optional accessories:

  • Spare Cylinder yoke, 1 O2, includes gauges × 1

  • Spare Cylinder yoke, 1 N2O, includes gauges × 1

  • Disposable Adult breathing circuit × 1

  • Disposable Pediatric breathing circuit × 1

  • Anesthetic gas scavenging system × 1

  • Patient monitor × 1

Applications:

Anesthesia system MD-ANS-1006 performs excellently in ICUs, operating rooms, and anesthesiology departments. It is professionally designed for adult, child, and infant inhalation anesthesia and respiratory management, featuring advanced ventilation modes.

Specifications:

Ventilation Modes IPPV, PCV-PC, PCV-VG, V-A/C, P-A/C, P-SIMV, V-SIMV, PSV, PCV-VG SIGH, MANUAL
Gas source O2, N2O, AIR
Flowmeter Range O2: 0.2 to 15 L/min
N2O: 0.2 to 12 L/min
AIR: 0.2 to 15 L/min
Rapid Oxygen Supply 25 L/min to 75 L/min
Oxygen Concentration Range 15 % to 100 %
Inspiratory Ratio (I) 4:1 to 1:8
Tidal Volume (Vt) range 0, 10 mL to 1500 mL
Minute Volume (MV) Range 0 L/min to 100 L/min
Frequency Range 0 /min to 120 /min
Positive End-Expiratory Pressure (PEEP) 0 cmH2O to 30 cmH2O
Pressure Control Range 5 cmH2O to 70 cmH2O
Pressure Triggering Sensitivity (PTr) -20 cmH2O to 0 cmH2O
Flow Trigger Sensitivity (FTr) OFF, 0.5 L/min to 30 L/min
Apnea Ventilation OFF, 5% to 60%
SIGH 0 (off) 1/100 to 5/100
Gas Pressure Range 280 kPa to 600 kPa
Pressure Limit 10 cmH2O to 100 cmH2O
Bellow 1L
Oscillogram Types P-T (Pressure-Time)
F-T (Flow-Time),
V-T (Volume-Time)
P-V loop (Pressure-Volume Loop)
ETCO2-T (ETCO2-Time)
F-V (Flow-Volume Loop)
F-P (Flow-Pressure Loop)
High-minute volume alarm Power supply Undervoltage alarm
Low-minute volume alarm Low tidal volume alarm
High airway pressure alarm Continuous pressure alarm
Low airway pressure alarm High-frequency alarm
No tidal volume Suffocation alarm
High tidal volume alarm Backup power alarm
Absorber disconnection alarm Battery exhausted alarm
High oxygen concentration alarm Fan error
Low oxygen concentration alarm Low oxygen supply alarm
High ETCO2 concentration alarm Low oxygen supply alarm
Power Consumption 85 VA
Power Supply Voltage: 100 to 240 V Power Frequency: 50/60 Hz
Packing Dimension 1005 × 960 × 1700 mm
Net Weight 126 kg
Gross Weight 253 kg
www.medicaldeals.com
>