DVT Air Compression Therapy System MD-AC-1000

DVT Air Compression Therapy System MD-AC-1000 features 12 sequential and uniform gradient compression modes. It can accommodate relative humidity up to 85%, without condensation. Includes sequential gradient for calf and 3-chamber leg sleeves, and uniform compression for 4-chamber leg sleeves. Our system’s user-friendly 7-inch color LCD touchscreen interface offers intuitive control and monitoring.

Features:

  • Vascular refill detection (VRD) technology
  • Precise pressure retaining
  • Diversified sleeves
  • Audible and visual alarms for safety
  • IPXO (IEC 529) water protection
  • Lithium-ion battery for portable use

Optional accessories:

Reusable 3-Chamber Leg Sleeve

Reusable 3-Chamber Calf Sleeve

Reusable 1-Chamber Left Foot Sleeve

Reusable 1-Chamber Right Foot Sleeve

Reusable 3-Chamber Arm Sleeve

Reusable 1-Chamber Left Hand Sleeve

Reusable 1-Chamber Right Hand Sleeve (Version)

Reusable 4-Chamber Leg Sleeve in Selectable Sizes: M, XL, XXL

Reusable 4-Chamber Arm Sleeve

Reusable 4-Chamber Abdomen Sleeve

10 Single Use 3-Chamber Leg Sleeve

10 Single 3-Chamber Calf Sleeve

10 Single 1-Chamber Left Foot Sleeve

10 Single 1-Chamber Right Foot Sleeve

10 Single 3-Chamber Arm Sleeve

10 Single 1-Chamber Left Hand Sleeve

10 Single 1-Chamber Right Hand Sleeve

Applications:

Our DVT Air Compression Therapy System is used in clinical settings for deep vein thrombosis (DVT) prophylaxis and lymphedema alleviation.

Specifications:
Mode of Operation Continuous
Operating Condition Temperature: 10°C to 40°C
Relative Humidity: 85% Maximum, non-condensing
Atmospheric Pressure: 700 mbar to 1060 mbar
Compression Type Calf/3-chamber leg sleeves: Sequential Gradient
4 Chamber leg sleeves: Uniform
Compression Cycle Leg Sleeves: 8-15 Seconds Compression
Foot Cuffs: 6-12 Seconds Compression
Pressure Range 4 levels adjustable (80 to 200 mmHg)
Falling Gradient Pressure Available
Sequential Compression Available
Decompression Time Based upon Vascular Refill Detection Measurement
Session Time 0 to 99 minutes
Number of Channels 2
Chambers in Single Cuff/Sleeves 1,3 or 4 optional
Type of Cuff/Sleeve Reusable or single-patient use optional
Cuff/Sleeve Positioning Foot, calf, thigh
Bed Hook Yes
Audible/Visual Alarms Low pressure, High pressure, Low battery
Power Cord Hospital Grade Plug
Noise 60 dB
Battery 7.4 V, 2600mAh, Lithium Ion
Run Time: 2-4 hours
Charge Time: 4 hours
Interface 7-inch color LCD touchscreen
Purposes DVT prophylaxis/Lymphedema alleviation
Transport and Storage Condition -10°C to 40° C
Power Consumption 42 W
Power Supply 100 to 240 VAC, 50VA, 50/60 Hz
Controller Dimensions (H×W×D) 18×19×19 cm
Packaging Dimensions (H×W×D) 27.3×24.1×28.6 cm
Controller Weight 1.5kg
Packaging Weight 3 Kg
www.medicaldeals.com
>