Fingertip Pulse Oximeter MD-FPO-1001

Fingertip Pulse Oximeter MD-FPO-1001 offers a measurement range of 70% to 100% for SpO₂, 30 bpm to 250 bpm for PR, 0.1% to 20% for PI and 4rpm to 45rpm for RR. It has a compact design with dimensions 61.5 × 32 × 31.5 ±3mm. It features a 1.12” OLED display, providing real-time visualization of SpO₂, PR, RR, PI, and waveform. It has dual display modes for flexibility. It is ideal for monitoring oxygen saturation and pulse rate in hospitals, home healthcare, and clinical settings, making it suitable for adults, adolescents, children, and infants.

Specifications

Display OLED
Parameters Peripheral oxygen saturation (SpO2)
Pulse rate (PR)
Perfusion Index (PI)
Respiratory Rate (RR)
SpO2 Measurement Range: 70% to 100%
Resolution: 1%
Accuracy: 70% to 100% ±2%; 0% to 69% No Definition
PR Measurement Range: 30 bpm to 250 bpm
Resolution: 1bpm
Accuracy: 30 bpm to 99 bpm ±2 bpm; 100 bpm to 250 bpm ±2%
PI Measurement Range: 0.1% to 20%
Resolution: 0.1%
RR Measurement Range: 4rpm to 45rpm
Mean Error: ±1rpm
Environmental Conditions Operation Temperature: 5℃ to 40℃
Operation Humidity: 15% to 93%, no condensation
Storage Temperature: -25℃ to +70℃
Storage Humidity: ≤93%, no condensation
Power Consumption Less than 40mA
Battery Two AAA-size 1.5V batteries
Dimensions 61.5 × 32 × 31.5 ±3mm
Weight 60±5g (including batteries)

Features

  • Compact and Lightweight Design
  • Easy Operation and Portable Design
  • Low Power Usage
  • Real-Time Battery Status Indicator
  • Smart BLE 4.0 Data Transmission
  • Automatic/Manual Power On/Off
  • Signal Instability Notification Alert
  • FDA and NMPA Certified

Optional Accessories

  • SpO₂ Sensor

Applications

Fingertip Pulse Oximeter MD-FPO-1001 is ideal for real-time tracking of respiratory health in hospitals, clinical settings, home healthcare, and fitness tracking. It is suitable for adults, adolescents, children, and infants.

Ask Our Experts

Fingertip Pulse Oximeter

Medical Deals Fingertip Pulse Oximeter offer non-invasive monitoring of peripheral oxygen saturation (SpO₂) and pulse rate (PR). They feature a sleek, compact design for comfortable use on the fingertip. Advanced light sensors measure changes in light absorption, distinguishing between oxygenated and deoxygenated hemoglobin. These oximeters are ideal for tracking respiratory health and are suitable for both personal and clinical use. Many models include multi-directional displays and adjustable brightness for convenient viewing. Our oximeters provide accurate, convenient monitoring for effective respiratory health management.

Fingertip Pulse Oximeter MD-FPO-1002

  • Display:LED
  • Parameters:Peripheral oxygen saturation (SpO2)
    Pulse rate (PR)
    Pulse Bar
  • SpO2:Measurement Range: 70% to 100%
    Resolution: 1%
    Accuracy: 70% to 100% ±2%; 0% to 69% No Definition
  • PR:Measurement Range: 30 bpm to 250 bpm
    Resolution: 1bpm
    Accuracy: 30 bpm to 99 bpm ±2 bpm; 100 bpm to 250 bpm ±2%
Get Quote

Fingertip Pulse Oximeter MD-FPO-1004

  • Display:OLED
  • Parameters:Peripheral oxygen saturation (SpO2)
    Pulse rate (PR)
    waveform
    Pulse Bar
  • SpO₂:Measurement Range: 70% to 100%
    Resolution: 1%
    Accuracy: 70% to 100% ±2%; 0% to 69% No Definition
  • PR:Measurement Range: 30 bpm to 250 bpm
    Resolution: 1bpm
    Accuracy: 30 bpm to 99 bpm ±2 bpm; 100 bpm to 250 bpm ±2%
Get Quote
Fingertip Pulse Oximeter MD-FPO-1000
  • Parameters:Peripheral oxygen saturation (SpO₂)
    Pulse rate (PR)
    Perfusion Index (PI)
  • SpO₂:Measurement range: 70% to 100%
    Resolution: 1%
    Accuracy: 70% to 100%: ±2%; 0% to 69%
  • PR:Measurement range: 30 to 250 bpm
    Resolution: 1 bpm
    Accuracy: 30bpm to 99bpm ±2bpm; 100 bpm to 250bpm ±2%
  • PI:0.3 to 20.0% 30 to 99bpm ±2bpm, 100 to 250bpm ±2%
Get Quote
Fingertip Pulse Oximeter MD-FPO-1003
  • Display:LCD
  • Parameters:Peripheral oxygen saturation (SpO2)
    Pulse rate (PR)
    Perfusion Index (PI)
  • SpO2:Measurement Range: 70% to 100%
    Resolution: 1%
    Accuracy: 70% to 100% ±2%; 0% to 69% No Definition
  • PR:Measurement Range: 30 bpm to 250 bpm
    Resolution: 1bpm
    Accuracy: 30 bpm to 99 bpm ±2 bpm; 100 bpm to 250 bpm ±2%
Get Quote