Anesthesia system MD-ANS-1002 offers an Inspiratory to Expiratory Ratio Configurable from 2:1 to 1:6. It provides the ability to fine-tune the breathing cycle. It also provides precise gas flow control for O2, N2O, and AIR, ranging from 0.1 to 10 L/min each. The system is designed for ease of operation with intuitive controls and a digital display. That provides real-time monitoring and alarm notifications. Our Anesthesia system is ideal for modern operating rooms, offering advanced control, flexibility, and safety features that cater to the diverse needs of patients.
| Ventilation Modes | IPPV, A/C, SIMV, SIGH, MANUAL |
| Gas Source | O2, N2O, AIR |
| Flowmeter range | O2: 0.1 to 10 L/min; N2O: 0.1 to 10 L/min AIR: 0.1 to 10 L/min |
| Rapid Oxygen Supply Range | 25 L/min to 75 L/min |
| Oxygen Concentration | 15 % to 100 % |
| Tidal Volume (Vt) range | 0, 20 mL to 1500 mL |
| Minute Volume (MV) | 0 L/min to 100 L/min |
| Maximum Minute Volume | ≥18 L/min |
| Frequency range | 1 /min to 100 /min |
| Inspiratory Ratio (I) | 2:1 - 1:6 |
| Positive End-Expiratory Pressure (PEEP) | 0 cmH2O to 30 cmH2O |
| Pressure Triggering Sensitivity (PTr) | -20 cmH2O to 20 cmH2O |
| Flow Trigger Sensitivity (FTr) | 0.5 L/min to 30 L/min |
| SIGH | 0 (off) 1/100 to 5/100 |
| Apnea Ventilation | OFF, 5 s to 60 s |
| Gas Pressure Range | 280 kPa to 600 kPa |
| Pressure Limit | 20 cmH2O to 100 cmH2O |
| Bellow | 1.5L |
| Oscillogram Types | P-T (Pressure-Time), F-T (Flow-Time), P-V loop (Pressure-Volume Loop) |
| AC Power Failure Alarm | Yes |
| Battery Backup Low Voltage Alarm | Yes; threshold < 11.3 ± 0.3 V |
| Tidal Volume Alarm | Triggered if no tidal volume is detected |
| High/Low Oxygen Concentration Alarm | 19 % to 100 % (High); 18 % to 99 % (Low) |
| Airway Pressure Alarms | High: 20 cmH2O to 100 cmH2O; Low: 0 cmH2O to 20 cmH2O |
| Minute Volume Alarms | Adult: 5 L/min to 20 L/min; Pediatric: 1 L/min to 15 L/min |
| Continuous Pressure Alarm | Over (PEEP + 1.5 kPa) for 16 s |
| Suffocation Warning | 5 s to 60 s with no spontaneous ventilation |
| Maximum Limited Pressure | ≤12.5 kPa |
| Fan Error, Oxygen Deficit, Power Failure | Displayed on screen |
| Display | 10.4"Colorful TFT LCD |
| Power Consumption | 80VA |
| Power Supply | Voltage: 100 to 240 V Power Frequency: 50/60 Hz |
| Packing Dimension | 920 × 970 × 1390 mm |
| Net Weight | 87.5 kg |
| Gross Weight | 155 kg |
10.4"Colorful TFT LCD
Adjustable ventilation rates
Rapid Oxygen Supply
SIGH: prevent atelectasis
Oscillogram Display
AC Power Failure Alarm
Internal Battery Backup
Low Voltage Alarm
Vaporizer Safety
Suffocation Warning
Power Failure or No Connection Alert
Anesthetic breathing system × 1
Power cord 4m × 1
Fuse × 2
Fuse × 1
O2 cell × 1
Breathing tube × 2
Breathing tube × 1
Breathing tube × 2
Y connector Adult × 1
Y connector Child × 1
L connector × 2
Straight connector (φ22 to φ22) × 1
Reservoir bag 1L × 1
Reservoir bag 3L × 1
Anesthetic mask adult × 1
Anesthetic mask infant × 1
Anesthesia Vaporizer × 1
High pressure O2 hose × 1
High-pressure AIR hose × 1
High pressure N2O hose × 1
CO2 sensor × 1
Transfer and receiving system of exhaust gas × 1
Patient monitor × 1
Anesthesia System MD-ANS-1002 offers high performance in ICUs, operating rooms, and anesthesiology ensuring maximum patient safety and ease of use across adult, child, and infant anesthesia and respiratory care.