Anaesthesia System MD-ANS-1002 Catalog

Overview

Anesthesia system MD-ANS-1002 offers an Inspiratory to Expiratory Ratio Configurable from 2:1 to 1:6. It provides the ability to fine-tune the breathing cycle. It also provides precise gas flow control for O2, N2O, and AIR, ranging from 0.1 to 10 L/min each. The system is designed for ease of operation with intuitive controls and a digital display. That provides real-time monitoring and alarm notifications. Our Anesthesia system is ideal for modern operating rooms, offering advanced control, flexibility, and safety features that cater to the diverse needs of patients.

Specifications :
Ventilation Modes IPPV, A/C, SIMV, SIGH, MANUAL
Gas Source O2, N2O, AIR
Flowmeter range O2: 0.1 to 10 L/min;
N2O: 0.1 to 10 L/min
AIR: 0.1 to 10 L/min
Rapid Oxygen Supply Range 25 L/min to 75 L/min
Oxygen Concentration 15 % to 100 %
Tidal Volume (Vt) range 0, 20 mL to 1500 mL
Minute Volume (MV) 0 L/min to 100 L/min
Maximum Minute Volume ≥18 L/min
Frequency range 1 /min to 100 /min
Inspiratory Ratio (I) 2:1 - 1:6
Positive End-Expiratory Pressure (PEEP) 0 cmH2O to 30 cmH2O
Pressure Triggering Sensitivity (PTr) -20 cmH2O to 20 cmH2O
Flow Trigger Sensitivity (FTr) 0.5 L/min to 30 L/min
SIGH 0 (off) 1/100 to 5/100
Apnea Ventilation OFF, 5 s to 60 s
Gas Pressure Range 280 kPa to 600 kPa
Pressure Limit 20 cmH2O to 100 cmH2O
Bellow 1.5L
Oscillogram Types P-T (Pressure-Time),
F-T (Flow-Time),
P-V loop (Pressure-Volume Loop)
AC Power Failure Alarm Yes
Battery Backup Low Voltage Alarm Yes; threshold < 11.3 ± 0.3 V
Tidal Volume Alarm Triggered if no tidal volume is detected
High/Low Oxygen Concentration Alarm 19 % to 100 % (High);
18 % to 99 % (Low)
Airway Pressure Alarms High: 20 cmH2O to 100 cmH2O;
Low: 0 cmH2O to 20 cmH2O
Minute Volume Alarms Adult: 5 L/min to 20 L/min;
Pediatric: 1 L/min to 15 L/min
Continuous Pressure Alarm Over (PEEP + 1.5 kPa) for 16 s
Suffocation Warning 5 s to 60 s with no spontaneous ventilation
Maximum Limited Pressure ≤12.5 kPa
Fan Error, Oxygen Deficit, Power Failure Displayed on screen
Display 10.4"Colorful TFT LCD
Power Consumption 80VA
Power Supply Voltage: 100 to 240 V
Power Frequency: 50/60 Hz
Packing Dimension 920 × 970 × 1390 mm
Net Weight 87.5 kg
Gross Weight 155 kg
Features :

  • 10.4"Colorful TFT LCD

  • Adjustable ventilation rates

  • Rapid Oxygen Supply

  • SIGH: prevent atelectasis

  • Oscillogram Display

  • AC Power Failure Alarm

  • Internal Battery Backup 

  • Low Voltage Alarm

  • Vaporizer Safety

  • Suffocation Warning

  • Power Failure or No Connection Alert

Standard Accessories :

  • Anesthetic breathing system × 1

  • Power cord 4m × 1

  • Fuse × 2

  • Fuse × 1

  • O2 cell × 1

  • Breathing tube × 2

  • Breathing tube × 1

  • Breathing tube × 2

  • Y connector Adult × 1

  • Y connector Child × 1

  • L connector × 2

  • Straight connector (φ22 to φ22) × 1

  • Reservoir bag 1L × 1

  • Reservoir bag 3L × 1

  • Anesthetic mask adult × 1

  • Anesthetic mask infant × 1

  • Anesthesia Vaporizer × 1

  • High pressure Ohose × 1

  • High-pressure AIR hose × 1

  • High pressure N2O hose × 1

Optional Accessories :

  • CO2 sensor × 1

  • Transfer and receiving system of exhaust gas × 1

  • Patient monitor × 1

Applications :

Anesthesia System MD-ANS-1002 offers high performance in ICUs, operating rooms, and anesthesiology ensuring maximum patient safety and ease of use across adult, child, and infant anesthesia and respiratory care.