Download Catalog For :
Anesthesia System MD-ANS-1003 features a rapid oxygen supply with adjustable flow rates from 0 to 10 L/min. It has multiple ventilation modes, including IPPV, A/C, PCV, SIMV, SIGH, and manual. It offers a high-precision flowmeter for immediate, accurate monitoring of fresh gas flow. The ventilator operates with a versatile range of tidal volumes from 20 mL to 1500 mL, with a frequency of 1 to 100 breaths per minute. Our Anesthesia System ensures enhanced safety and flexibility ideal for anesthesia and critical care settings.
Features:
Instant and accurate monitoring
Adjustable oxygen flow rate
Adjustable PEEP
Comprehensive Pressure control settings
Adjustable Breathing Frequency
Integrated breathing circuit design
10.4" TFT LCD screen display
High precision flowmeter
Patient-centered ventilation
Low-pressure alarm cut-off protection.
Compact design
Standard accessories:
Anesthetic breathing system × 1
Power cord × 1
Fuse × 2
Fuse × 1
O2 sensor × 1
Breathing tube × 2
Breathing tube × 1
Breathing tube × 2
Y connector Adult × 1
Y connector Child × 1
L connector × 2
Straight connector (φ22 to φ22) × 1
Reservoir bag 1L × 1
Reservoir bag 3L × 1
Anesthetic mask adult × 1
Anesthetic mask infant × 1
Anesthesia Vaporizer × 1
High pressure O2 hose × 1
High-pressure AIR hose × 1
High pressure N2O hose × 1
Optional accessories:
Transfer and receiving system of exhaust gas × 1
CO2 Sensor × 1
Patient monitor × 1
Applications:
Anesthesia System MD-ANS-1003 delivers exceptional performance in (ICUs), operating rooms, and other clinical settings, this machine offers top-tier safety, stability, and user convenience, ensuring an excellent experience for clinicians.
Specifications:
Ventilation Modes | IPPV, PCV, A/C, SIMV, SIGH, MANUAL |
---|---|
Gas Source | O2, N2O |
Flowmeter range | O22: 0 to 10 L/min; N2O: 0 to 10 L/min |
Rapid Oxygen Supply Range | 25 L/min to 75 L/min |
Oxygen Concentration | 15 % to 100 % |
Tidal Volume (Vt) range | 0, 20 mL to 1500 mL |
Frequency range | 1 /min to 100 /min |
Inspiratory Ratio (I) | 0.2s to 6s 2:1 - 1:6 |
Minute Volume (MV) | 0 L/min to 100 L/min |
Positive End-Expiratory Pressure (PEEP) | 0 cmH2O to 30 cmH2O |
Pressure Triggering Sensitivity (PTr) | -20 cmH2O to 20 cmH2O |
Flow Trigger Sensitivity (FTr) | 0.5 L/min to 30 L/min |
SIGH | 0 (off) 1/100 to 5/100 |
Apnea Ventilation | OFF, 5 s to 60 s |
Gas Pressure Range | 280 kPa to 600 kPa |
Pressure Limit | 20 cmH,sub>2O to 100 cmH2O |
Oscillogram Types | P-T (Pressure-Time), F-T (Flow-Time), V-T (Volume-Time) P-V loop (Pressure-Volume Loop) F-V (Flow-Volume Loop) F-P (Flow-Pressure Loop) ETCO2-T (ETCO2-Time) |
The AC power failure alarm | Power failure or no connection |
Low voltage alarm for backup battery | < 11.3 ± 0.3 V |
No tidal volume | ≤ 5 mL within 6 s |
High oxygen concentration alarm | 19% to 100% |
Low oxygen concentration alarm | 18% to 99% |
High airway pressure alarm | 20 cmH2O to 100 cmH2O |
Low airway pressure alarm | 0 cmH2O to 20 cmH2O |
High-minute volume alarm | Adult (5 L/min to 20 L/min) |
Low-minute volume alarm | Paed (1 L/min to 15 L/min, 0 ~ 10 L/min) |
Continuous pressure alarm | (PEEP+1.5 kPa) over 16s |
Suffocation warning | 5s-60s no spontaneous ventilation |
The maximum limited pressure | ≤ 12.5 kPa |
Fan error | Show on screen |
Oxygen deficit | Show on screen |
Power Consumption | 85 VA |
Power Supply | Voltage: 100 to 240 V Power Frequency: 50/60 Hz |
Packing Dimension | 740 × 795 × 1540 mm |
Net Weight | 52.5 kg |
Gross Weight | 119 kg |