Anesthesia System MD-ANS-1003 features a rapid oxygen supply with adjustable flow rates from 0 to 10 L/min. It has multiple ventilation modes, including IPPV, A/C, PCV, SIMV, SIGH, and manual. It offers a high-precision flowmeter for immediate, accurate monitoring of fresh gas flow. The ventilator operates with a versatile range of tidal volumes from 20 mL to 1500 mL, with a frequency of 1 to 100 breaths per minute. Our Anesthesia System ensures enhanced safety and flexibility ideal for anesthesia and critical care settings.
Specifications
| Ventilation Modes | IPPV, PCV, A/C, SIMV, SIGH, MANUAL |
| Gas Source | O2, N2O |
| Flowmeter range | O22: 0 to 10 L/min; N2O: 0 to 10 L/min |
| Rapid Oxygen Supply Range | 25 L/min to 75 L/min |
| Oxygen Concentration | 15 % to 100 % |
| Tidal Volume (Vt) range | 0, 20 mL to 1500 mL |
| Frequency range | 1 /min to 100 /min |
| Inspiratory Ratio (I) | 0.2s to 6s 2:1 - 1:6 |
| Minute Volume (MV) | 0 L/min to 100 L/min |
| Positive End-Expiratory Pressure (PEEP) | 0 cmH2O to 30 cmH2O |
| Pressure Triggering Sensitivity (PTr) | -20 cmH2O to 20 cmH2O |
| Flow Trigger Sensitivity (FTr) | 0.5 L/min to 30 L/min |
| SIGH | 0 (off) 1/100 to 5/100 |
| Apnea Ventilation | OFF, 5 s to 60 s |
| Gas Pressure Range | 280 kPa to 600 kPa |
| Pressure Limit | 20 cmH,sub>2O to 100 cmH2O |
| Oscillogram Types | P-T (Pressure-Time), F-T (Flow-Time), V-T (Volume-Time) P-V loop (Pressure-Volume Loop) F-V (Flow-Volume Loop) F-P (Flow-Pressure Loop) ETCO2-T (ETCO2-Time) |
| The AC power failure alarm | Power failure or no connection |
| Low voltage alarm for backup battery | < 11.3 ± 0.3 V |
| No tidal volume | ≤ 5 mL within 6 s |
| High oxygen concentration alarm | 19% to 100% |
| Low oxygen concentration alarm | 18% to 99% |
| High airway pressure alarm | 20 cmH2O to 100 cmH2O |
| Low airway pressure alarm | 0 cmH2O to 20 cmH2O |
| High-minute volume alarm | Adult (5 L/min to 20 L/min) |
| Low-minute volume alarm | Paed (1 L/min to 15 L/min, 0 ~ 10 L/min) |
| Continuous pressure alarm | (PEEP+1.5 kPa) over 16s |
| Suffocation warning | 5s-60s no spontaneous ventilation |
| The maximum limited pressure | ≤ 12.5 kPa |
| Fan error | Show on screen |
| Oxygen deficit | Show on screen |
| Power Consumption | 85 VA |
| Power Supply | Voltage: 100 to 240 V Power Frequency: 50/60 Hz |
| Packing Dimension | 740 × 795 × 1540 mm |
| Net Weight | 52.5 kg |
| Gross Weight | 119 kg |
Features
Instant and accurate monitoring
Adjustable oxygen flow rate
Adjustable PEEP
Comprehensive Pressure control settings
Adjustable Breathing Frequency
Integrated breathing circuit design
10.4" TFT LCD screen display
High precision flowmeter
Patient-centered ventilation
Low-pressure alarm cut-off protection.
Compact design
Standard Accessories
Anesthetic breathing system × 1
Power cord × 1
Fuse × 2
Fuse × 1
O2 sensor × 1
Breathing tube × 2
Breathing tube × 1
Breathing tube × 2
Y connector Adult × 1
Y connector Child × 1
L connector × 2
Straight connector (φ22 to φ22) × 1
Reservoir bag 1L × 1
Reservoir bag 3L × 1
Anesthetic mask adult × 1
Anesthetic mask infant × 1
Anesthesia Vaporizer × 1
High pressure O2 hose × 1
High-pressure AIR hose × 1
High pressure N2O hose × 1
Optional Accessories
Transfer and receiving system of exhaust gas × 1
CO2 Sensor × 1
Patient monitor × 1
Applications
Anesthesia System MD-ANS-1003 delivers exceptional performance in (ICUs), operating rooms, and other clinical settings, this machine offers top-tier safety, stability, and user convenience, ensuring an excellent experience for clinicians.
Anesthesia System is an advanced, user-friendly anesthesia delivery system designed to meet the needs of modern healthcare facilities. Engineered for safety, accuracy, and efficiency, it features an intuitive touchscreen interface. It allows seamless control and monitoring of anesthesia parameters. With precise gas flow meters and integrated safety alarms, the system ensures optimal delivery of anesthetic gases while prioritizing patient safety. Built with adaptability in mind, Our system provides Precision Care system support for a range of patient types, from pediatric to adult.