Anesthesia System MD-ANS-1003 features a rapid oxygen supply with adjustable flow rates from 0 to 10 L/min. It has multiple ventilation modes, including IPPV, A/C, PCV, SIMV, SIGH, and manual. It offers a high-precision flowmeter for immediate, accurate monitoring of fresh gas flow. The ventilator operates with a versatile range of tidal volumes from 20 mL to 1500 mL, with a frequency of 1 to 100 breaths per minute. Our Anesthesia System ensures enhanced safety and flexibility ideal for anesthesia and critical care settings.

Ventilation Modes IPPV, PCV, A/C, SIMV, SIGH, MANUAL
Gas Source O2, N2O
Flowmeter range O22: 0 to 10 L/min;
N2O: 0 to 10 L/min
Rapid Oxygen Supply Range 25 L/min to 75 L/min
Oxygen Concentration 15 % to 100 %
Tidal Volume (Vt) range 0, 20 mL to 1500 mL
Frequency range 1 /min to 100 /min
Inspiratory Ratio (I) 0.2s to 6s 2:1 - 1:6
Minute Volume (MV) 0 L/min to 100 L/min
Positive End-Expiratory Pressure (PEEP) 0 cmH2O to 30 cmH2O
Pressure Triggering Sensitivity (PTr) -20 cmH2O to 20 cmH2O
Flow Trigger Sensitivity (FTr) 0.5 L/min to 30 L/min
SIGH 0 (off) 1/100 to 5/100
Apnea Ventilation OFF, 5 s to 60 s
Gas Pressure Range 280 kPa to 600 kPa
Pressure Limit 20 cmH,sub>2O to 100 cmH2O
Oscillogram Types P-T (Pressure-Time),
F-T (Flow-Time),
V-T (Volume-Time)
P-V loop (Pressure-Volume Loop)
F-V (Flow-Volume Loop)
F-P (Flow-Pressure Loop)
ETCO2-T (ETCO2-Time)
The AC power failure alarm Power failure or no connection
Low voltage alarm for backup battery < 11.3 ± 0.3 V
No tidal volume ≤ 5 mL within 6 s
High oxygen concentration alarm 19% to 100%
Low oxygen concentration alarm 18% to 99%
High airway pressure alarm 20 cmH2O to 100 cmH2O
Low airway pressure alarm 0 cmH2O to 20 cmH2O
High-minute volume alarm Adult (5 L/min to 20 L/min)
Low-minute volume alarm Paed (1 L/min to 15 L/min, 0 ~ 10 L/min)
Continuous pressure alarm (PEEP+1.5 kPa) over 16s
Suffocation warning 5s-60s no spontaneous ventilation
The maximum limited pressure ≤ 12.5 kPa
Fan error Show on screen
Oxygen deficit Show on screen
Power Consumption 85 VA
Power Supply Voltage: 100 to 240 V
Power Frequency: 50/60 Hz
Packing Dimension 740 × 795 × 1540 mm
Net Weight 52.5 kg
Gross Weight 119 kg
    • Instant and accurate monitoring

    • Adjustable oxygen flow rate

    • Adjustable PEEP 

    • Comprehensive Pressure control settings

    • Adjustable Breathing Frequency

    • Integrated breathing circuit design

    • 10.4" TFT LCD screen display

    • High precision flowmeter

    • Patient-centered ventilation

    • Low-pressure alarm cut-off protection.

    • Compact design

    • Anesthetic breathing system × 1

    • Power cord × 1

    • Fuse × 2

    • Fuse × 1

    • O2 sensor × 1

    • Breathing tube × 2

    • Breathing tube × 1

    • Breathing tube × 2

    • Y connector Adult × 1

    • Y connector Child × 1

    • L connector × 2

    • Straight connector (φ22 to φ22) × 1

    • Reservoir bag 1L × 1

    • Reservoir bag 3L × 1

    • Anesthetic mask adult × 1

    • Anesthetic mask infant × 1

    • Anesthesia Vaporizer × 1

    • High pressure Ohose × 1

    • High-pressure AIR hose × 1

    • High pressure N2O hose × 1

    • Transfer and receiving system of exhaust gas × 1

    • CO2 Sensor × 1

    • Patient monitor × 1