Anaesthesia System MD-ANS-1000

Anaesthesia System MD-ANS-1000

$6,804

Anesthesia System MD-ANS-1000 features a tidal volume between 20 mL and 1500 mL and a frequency from 1/min to 100/min. It offers adjustable ventilation modes, including PV, A/C, SIMV, and SIGH. Apnea ventilation and SIGH functionality. The advanced system offers a variety of ventilation modes and adjustable parameters, ensuring precise control and customized care to meet the specific needs of each patient. Our Anesthesia system offers a Rapid oxygen supply ensuring great ventilation support, along with precision, and safety.

Ventilation Modes IPPV, A/C, SIMV, SIGH, MANUAL
Gas Source O<sub>2</sub>, N<sub>2</sub>O
Flowmeter range O<sub>2</sub>: 0 to 10 L/min;<br> N<sub>2</sub>O: 0 to 10 L/min
Rapid Oxygen Supply Range 25 L/min to 75 L/min
Oxygen Concentration 15 % to 100 %
Tidal Volume Range 0, 20 mL to 1500 mL
Frequency range 1 /min to 100 /min
Minute Volume (MV) 0 L/min to 100 L/min
Maximum Minute Volume ≥18 L/min
Inspiratory Ratio (I) 2:1 - 1:6
Positive End-Expiratory Pressure (PEEP) 0 cmH<sub>2</sub>O to 30 cmH<sub>2</sub>O
Pressure Triggering Sensitivity (PTr) -20 cmH<sub>2</sub>O to 20 cmH<sub>2</sub>O (Based on PEEP)
Flow Trigger Sensitivity (FTr) 0.5 L/min to 30 L/min
SIGH 0 (off) 1/100 to 5/100
Apnea Ventilation OFF, 5 s to 60 s
Gas Pressure Range 280 kPa to 600 kPa
Pressure Limit 20 cmH<sub>2</sub>O to 100 cmH<sub>2</sub>O
Bellow 1.5L
Oscillogram Types P-T (Pressure-Time),<br> F-T (Flow-Time),<br> P-V loop (Pressure-Volume Loop)
AC Power Failure Alarm Yes
Battery Backup Low Voltage Alarm Yes; threshold < 11.3 ± 0.3 V
Tidal Volume Alarm Triggered if no tidal volume is detected
High/Low Oxygen Concentration Alarm 19 % to 100 % (High);<br> 18 % to 99 % (Low)
Airway Pressure Alarms High: 20 cmH<sub>2</sub>O to 100 cmH<sub>2</sub>O;<br> Low: 0 cmH2O to 20 cmH2O
Minute Volume Alarms Adult: 5 L/min to 20 L/min;<br> Pediatric: 1 L/min to 15 L/min
Continuous Pressure Alarm Over (PEEP + 1.5 kPa) for 16 s
Suffocation Warning 5 s to 60 s with no spontaneous ventilation
Maximum Limited Pressure < 12.5 kPa
Fan Error, Oxygen Deficit, Power Failure Displayed on screen
Display 7" TFT LCD screen display
Power Consumption 40VA
Power Supply Voltage: 100 to 240 V Power Frequency: 50/60 Hz
Package Dimension 790 × 740 × 1460 mm
Net Weight 76 kg
Gross Weight 103 kg
    • 7" TFT LCD screen display

    • Frequency: 1 to 100 breaths per minute

    • Precise control of gas flow

    • Rapid Oxygen Supply

    • 7" TFT LCD screen display

    • Provides visual oscillograms

    • Integrated breathing circuit design

    • Equipped with comprehensive safety alarms

    • Battery Backup 

    • Power Failure Alarms

    • Low O2 pressure alarm and N2O cut-off protection.

    • Compact and durable design

    • Anesthetic breathing system × 1

    • Power cord 4m × 1

    • Fuse 50V × 2

    • Fuse × 1

    • O2 cell × 1

    • Adult Anesthesia Breathing Circuit(reusable) × 2

    • Child Anesthesia Breathing Circuit(reusable) × 2

    • Breathing tube × 1

    • Y connector × 1

    • Y connector × 1

    • L connector × 1

    • Straight connector × 1

    • Reservoir bag 1L × 1

    • Reservoir bag 3L × 1

    • Anesthetic mask adult × 1

    • Anesthetic mask infant × 1

    • Anesthesia Vaporizer × 2

    • High pressure Ohose × 1

    • High-pressure AIR hose × 1

    • Gasket × 1

    • Gasket × 2

    • Disposable Adult breathing circuit × 1

    • Disposable Pediatric breathing circuit × 1

    • Transfer and receiving system of exhaust gas × 1

    • Patient monitor × 1

  • Our Anesthesia System MD-ANS-1000 is designed for use in Intensive Care Units (ICUs), operating rooms, anesthesiology departments, and other specialized areas such as pediatric and geriatric care, patients who require ventilatory support, including those suffering from respiratory failure, trauma, or those undergoing emergency surgeries.

Ask Our Experts
Captcha Image

Anesthesia System

Frequently Asked Questions

How does an anesthesia system work?

Anesthesia System deliver a precise mixture of gases and agents to the patient through a breathing circuit. The ventilator helps control respiration, and monitoring devices track vital signs during the procedure.

What is the purpose of a vaporizer in an anesthesia system?

Vaporizers convert liquid anesthetic agents into vapours and precisely mix them with carrier gases (like oxygen or air) for patient administration.

What are some common problems that can occur with anesthesia system?

Common problems include leaks in the breathing circuit, malfunctions in the vaporizers, and issues with the ventilator.

How are problems with anesthesia system diagnosed and repaired?

Anesthesia technicians and engineers are trained to diagnose and repair problems with these machines.

What is the pipeline pressure in an anesthesia system?

The pipeline pressure is 50-55 PSI. It is kept slightly higher than the cylinder pressure to ensure a continuous supply of gases. 10.

What is the purpose of a vaporizer on an anesthesia system?

Vaporizers deliver a controlled amount of anesthetic liquid into the gas stream, allowing for precise administration of the anesthetic agent.

What is fresh gas flow in an anesthesia system

Fresh gas flow refers to the continuous supply of gases and anesthetic agents delivered to the patient through the breathing circuit.

What is the purpose of a vaporizer in an anesthesia system?

Vaporizers convert liquid anesthetic agents into vapours and precisely mix them with carrier gases (like oxygen or air) for patient administration.

>