$13,848
Anesthesia System MD-ANS-1005 offers precise pressure control from -20 to 0 cmH2O and flow sensitivity between 0.5 and 30 L/min. It ensures smooth interaction with the patient's breathing. It supports various respiratory needs with adjustable parameters, including tidal volume (20 to 1500 mL). This system also offers a full range of customizable ventilation modes. Our System provides efficient anesthesia delivery ideal for both adult and pediatric patients.
Ventilation Modes | IPPV, PCV, A/C, SIMV, SIGH, MANUAL |
Gas Source | O2, N2O, AIR |
Flowmeter range | O2: 0 to 10 L/min N2O: 0 to 10 L/min |
Rapid Oxygen Supply Range | 25 L/min to 75 L/min |
Oxygen Concentration Range | 15 % to 100 % |
Inspiratory Ratio (I) | VTH 4:1 to 1:8 VTL 2:1 to 1:8 |
Tidal Volume Range | 0, 20 mL to 1500 mL |
Minute Volume | ≥18 L/min |
Frequency range | 1 breath /min to 100 breath /min |
Positive End-Expiratory Pressure (PEEP) | 0 cmH2O to 30 cmH2O |
Pressure control (PC) | 5 cmH2O to 60 cmH2O |
Pressure Triggering Sensitivity (PTr) | -20 cmH2O to 0 cmH2O |
Flow Trigger Sensitivity (FTr) | 0.5 L/min to 30 L/min |
Apnea Ventilation | OFF, 5 s to 60 s |
SIGH | 0 (off) 1/100 to 5/100 |
Gas Pressure Range | 280 kPa to 600 kPa |
Pressure Limit | 20 cmH2O to 100 cmH2O |
Bellow | 1.5L |
Oscillogram Types | P-T (Pressure-Time) F-T (Flow-Time) V-T (Volume-Time) P-V loop (Pressure-Volume Loop) F-V (Flow-Volume Loop) P - F (Pressure - Flow Loop) ETCO2-T (ETCO2-Time) |
The AC power failure alarm | Power failure or no connection |
Low voltage alarm for backup battery | < 10.2 ± 0.3 V |
No tidal volume | ≤ 5 mL within 6 s |
High oxygen concentration alarm Range | 19% to 100% |
Low oxygen concentration alarm Range | 18% to 99% |
High airway pressure alarm Range | 20 cmH2O to 100 cmH2O |
Low airway pressure alarm Range | 0 cmH2O to 20 cmH2O |
High-minute volume alarm Range | Adult (5 L/min to 20 L/min) |
Low-minute volume alarm Range | Paed (1 L/min to 15 L/min, 0 to 10 L/min) |
Continuous pressure alarm Range | (PEEP+1.5 kPa) over 16s |
Suffocation warning | 5s to 60s no spontaneous ventilation |
The maximum limited pressure | ≤ 12.5 kPa |
Fan error | Display on screen |
Oxygen deficit | Display on screen |
Display | 12.1" TFT LCD touchscreen |
Power Consumption | 85 VA |
Power Supply | Voltage: 100 to 240 V Power Frequency: 50/60 Hz |
Packing Dimension | 1005 × 960 × 1700 mm |
Net Weight | 116.5 kg |
Gross Weight | 227 kg |
customizable ventilation modes
adjustable parameters
advanced monitoring
A fan error alarm
12.1" TFT LCD touchscreen
Integrated breathing circuit design
High-precision electronic flowmeter
ACGO and fast oxygen supply
Automatic decompression to ensure safety.
Built-in Battery Backup
Compact and Light-weight
Anesthetic breathing system × 1
Power cord × 1
Fuse × 8
Fuse × 1
O2 cell × 1
CO2 sensor
Breathing tube × 2
Breathing tube × 1
Breathing tube × 2
Y connector Adult × 1
Y connector Child × 1
L connector × 2
Straight connector (φ22 to φ22) × 1
Reservoir bag 1L × 1
Reservoir bag 3L × 1
Anesthetic mask adult × 1
Anesthetic mask infant × 1
Anesthesia Vaporizer × 1
High pressure O2 hose × 1
High-pressure AIR hose × 1
High pressure N2O hose × 1
Transfer and receiving system of exhaust gas × 1
Patient monitor × 1
Our Anesthesia System MD-ANS-1005 excels in various clinical settings such as ICUs, operating rooms, and anesthesiology departments, it provides a comprehensive range of advanced ventilation modes and customized respiratory management solutions.