• Anesthesia System MD-ANS-1005
  • Anesthesia System MD-ANS-1005
Anesthesia System MD-ANS-1005

Anesthesia System MD-ANS-1005

$13,848

Anesthesia System MD-ANS-1005 offers precise pressure control from -20 to 0 cmH2O and flow sensitivity between 0.5 and 30 L/min. It ensures smooth interaction with the patient's breathing. It supports various respiratory needs with adjustable parameters, including tidal volume (20 to 1500 mL). This system also offers a full range of customizable ventilation modes. Our System provides efficient anesthesia delivery ideal for both adult and pediatric patients.

Ventilation Modes IPPV, PCV, A/C, SIMV, SIGH, MANUAL
Gas Source O2, N2O, AIR
Flowmeter range O2: 0 to 10 L/min
N2O: 0 to 10 L/min
Rapid Oxygen Supply Range 25 L/min to 75 L/min
Oxygen Concentration Range 15 % to 100 %
Inspiratory Ratio (I) VTH 4:1 to 1:8 VTL 2:1 to 1:8
Tidal Volume Range 0, 20 mL to 1500 mL
Minute Volume ≥18 L/min
Frequency range 1 breath /min to 100 breath /min
Positive End-Expiratory Pressure (PEEP) 0 cmH2O to 30 cmH2O
Pressure control (PC) 5 cmH2O to 60 cmH2O
Pressure Triggering Sensitivity (PTr) -20 cmH2O to 0 cmH2O
Flow Trigger Sensitivity (FTr) 0.5 L/min to 30 L/min
Apnea Ventilation OFF, 5 s to 60 s
SIGH 0 (off) 1/100 to 5/100
Gas Pressure Range 280 kPa to 600 kPa
Pressure Limit 20 cmH2O to 100 cmH2O
Bellow 1.5L
Oscillogram Types P-T (Pressure-Time)
F-T (Flow-Time)
V-T (Volume-Time)
P-V loop (Pressure-Volume Loop)
F-V (Flow-Volume Loop)
P - F (Pressure - Flow Loop)
ETCO2-T (ETCO2-Time)
The AC power failure alarm Power failure or no connection
Low voltage alarm for backup battery < 10.2 ± 0.3 V
No tidal volume ≤ 5 mL within 6 s
High oxygen concentration alarm Range 19% to 100%
Low oxygen concentration alarm Range 18% to 99%
High airway pressure alarm Range 20 cmH2O to 100 cmH2O
Low airway pressure alarm Range 0 cmH2O to 20 cmH2O
High-minute volume alarm Range Adult (5 L/min to 20 L/min)
Low-minute volume alarm Range Paed (1 L/min to 15 L/min, 0 to 10 L/min)
Continuous pressure alarm Range (PEEP+1.5 kPa) over 16s
Suffocation warning 5s to 60s no spontaneous ventilation
The maximum limited pressure ≤ 12.5 kPa
Fan error Display on screen
Oxygen deficit Display on screen
Display 12.1" TFT LCD touchscreen
Power Consumption 85 VA
Power Supply Voltage: 100 to 240 V Power Frequency: 50/60 Hz
Packing Dimension 1005 × 960 × 1700 mm
Net Weight 116.5 kg
Gross Weight 227 kg
    • customizable ventilation modes 

    • adjustable parameters

    • advanced monitoring

    • A fan error alarm 

    • 12.1" TFT LCD touchscreen

    • Integrated breathing circuit design

    • High-precision electronic flowmeter

    • ACGO and fast oxygen supply

    • Automatic decompression to ensure safety.

    • Built-in Battery Backup

    • Compact and Light-weight

    • Anesthetic breathing system × 1

    • Power cord × 1

    • Fuse × 8

    • Fuse × 1

    • O2 cell × 1

    • CO2 sensor

    • Breathing tube × 2

    • Breathing tube × 1

    • Breathing tube × 2

    • Y connector Adult × 1

    • Y connector Child × 1

    • L connector × 2

    • Straight connector (φ22 to φ22) × 1

    • Reservoir bag 1L × 1

    • Reservoir bag 3L × 1

    • Anesthetic mask adult × 1

    • Anesthetic mask infant × 1

    • Anesthesia Vaporizer × 1

    • High pressure Ohose × 1

    • High-pressure AIR hose × 1

    • High pressure N2O hose × 1

    • Transfer and receiving system of exhaust gas × 1

    • Patient monitor × 1

  • Our Anesthesia System MD-ANS-1005 excels in various clinical settings such as ICUs, operating rooms, and anesthesiology departments, it provides a comprehensive range of advanced ventilation modes and customized respiratory management solutions.

Ask Our Experts

Captcha Image

Customer Reviews

Submit Your Review

Related Products

Frequently Asked Questions