Anesthesia System
Anesthesia System is an advanced, user-friendly anesthesia delivery system designed to meet the needs of modern healthcare facilities. Engineered for safety, accuracy, and efficiency, it features an intuitive touchscreen interface. It allows seamless control and monitoring of anesthesia parameters. With precise gas flow meters and integrated safety alarms, the system ensures optimal delivery of anesthetic gases while prioritizing patient safety. Built with adaptability in mind, Our system provides Precision Care system support for a range of patient types, from pediatric to adult.
Anaesthesia System MD-ANS-1000
-
Ventilation Modes : IPPV, A/C, SIMV, SIGH, MANUAL
-
Gas Source : O2, N2O
-
Flowmeter range : O2: 0 to 10 L/min;
N2O: 0 to 10 L/min
-
Rapid Oxygen Supply Range : 25 L/min to 75 L/min
-
Oxygen Concentration : 15 % to 100 %
-
Tidal Volume Range : 0, 20 mL to 1500 mL
-
Frequency range : 1 /min to 100 /min
-
Minute Volume (MV) : 0 L/min to 100 L/min
-
Maximum Minute Volume : ≥18 L/min
-
Inspiratory Ratio (I) : 2:1 - 1:6
-
Positive End-Expiratory Pressure (PEEP) : 0 cmH2O to 30 cmH2O
-
Pressure Triggering Sensitivity (PTr) : -20 cmH2O to 20 cmH2O (Based on PEEP)
-
Flow Trigger Sensitivity (FTr) : 0.5 L/min to 30 L/min
-
SIGH : 0 (off) 1/100 to 5/100
-
Apnea Ventilation : OFF, 5 s to 60 s
-
Gas Pressure Range : 280 kPa to 600 kPa
-
Pressure Limit : 20 cmH2O to 100 cmH2O
-
Bellow : 1.5L
-
Oscillogram Types : P-T (Pressure-Time),
F-T (Flow-Time),
P-V loop (Pressure-Volume Loop)
-
AC Power Failure Alarm : Yes
-
Battery Backup Low Voltage Alarm : Yes; threshold < 11.3 ± 0.3 V
-
Tidal Volume Alarm : Triggered if no tidal volume is detected
-
High/Low Oxygen Concentration Alarm : 19 % to 100 % (High);
18 % to 99 % (Low)
-
Airway Pressure Alarms : High: 20 cmH2O to 100 cmH2O;
Low: 0 cmH2O to 20 cmH2O
-
Minute Volume Alarms : Adult: 5 L/min to 20 L/min;
Pediatric: 1 L/min to 15 L/min
-
Continuous Pressure Alarm : Over (PEEP + 1.5 kPa) for 16 s
-
Suffocation Warning : 5 s to 60 s with no spontaneous ventilation
-
Maximum Limited Pressure : < 12.5 kPa
-
Fan Error, Oxygen Deficit, Power Failure : Displayed on screen
-
Display : 7" TFT LCD screen display
-
Power Consumption : 40VA
-
Power Supply : Voltage: 100 to 240 V Power Frequency: 50/60 Hz
-
Package Dimension : 790 × 740 × 1460 mm
-
Net Weight : 76 kg
-
Gross Weight : 103 kg
Anesthesia System MD-ANS-1001
-
Ventilation Modes : IPPV, A/C, SIMV, SIGH, MANUAL
-
Gas Source : O2, N2O, AIR
-
Flowmeter range : O2: 0.1 to 10 L/min;
N2O: 0.1 to 10 L/min
AIR: 0.1 to 10L/min
-
Rapid Oxygen Supply Range : 25 L/min to 75 L/min
-
Oxygen Concentration : 15 % to 100 %
-
Tidal Volume (Vt) range : 0, 20 mL to 1500 mL
-
Frequency range : 1 /min to 100 /min
-
Inspiratory Ratio (I.E) : 2:1 - 1:6
-
Minute Volume (MV) : 0 L/min to 100 L/min
-
Positive End-Expiratory Pressure (PEEP) : 0 cmH2O to 30 cmH2O
-
Pressure Triggering Sensitivity (PTr) : -20 cmH2O to 20 cmH2O (Based on PEEP)
-
Flow Trigger Sensitivity (FTr) : 0.5 L/min to 30 L/min
-
SIGH : 0 (off) 1/100 to 5/100
-
Apnea Ventilation : OFF, 5 s to 60 s
-
Gas Pressure Range : 280 kPa to 600 kPa
-
Pressure Limit : 20 cmH2O to 100 cmH2O
-
Bellow : 1.5L
-
Oscillogram Types : P-T (Pressure-Time),
F-T (Flow-Time),
P-V loop (Pressure-Volume Loop)
-
The AC power failure alarm : Power failure or no connection
-
Alarm for backup battery : < 11.3 ± 0.3 V
-
No tidal volume : ≤ 5 mL within 6 s
-
High oxygen concentration alarm : 19% to 100%
-
Low oxygen concentration alarm : 18% to 99%
-
High airway pressure alarm : 20 cmH2O to 100 cmH2O
-
Low airway pressure alarm : 0 cmH2O to 20 cmH2O
-
High-minute volume alarm : Adult (5 L/min - 20 L/min)
-
Low-minute volume alarm : Paed (1 L/min - 15 L/min, 0 - 10 L/min)
-
Continuous pressure alarm : (PEEP+1.5 kPa) over 16s
-
Suffocation warning : 5 s – 60 s no spontaneous ventilation
-
The maximum limited pressure : < 12.5 kPa
-
Fan error : Shows on screen
-
Oxygen deficit : Shows on screen
-
Display : 7-inch LED screen
-
Power Consumption : 40 VA
-
Power Supply : Voltage: 100 to 240 V Power Frequency: 50/60 Hz
-
Packing Dimension : 760 × 970 × 1550 mm
-
Net Weight : 82.5 kg
-
Gross Weight : 143 kg
Anaesthesia System MD-ANS-1002
-
Ventilation Modes : IPPV, A/C, SIMV, SIGH, MANUAL
-
Gas Source : O2, N2O, AIR
-
Flowmeter range : O2: 0.1 to 10 L/min;
N2O: 0.1 to 10 L/min
AIR: 0.1 to 10 L/min
-
Rapid Oxygen Supply Range : 25 L/min to 75 L/min
-
Oxygen Concentration : 15 % to 100 %
-
Tidal Volume (Vt) range : 0, 20 mL to 1500 mL
-
Minute Volume (MV) : 0 L/min to 100 L/min
-
Maximum Minute Volume : ≥18 L/min
-
Frequency range : 1 /min to 100 /min
-
Inspiratory Ratio (I) : 2:1 - 1:6
-
Positive End-Expiratory Pressure (PEEP) : 0 cmH2O to 30 cmH2O
-
Pressure Triggering Sensitivity (PTr) : -20 cmH2O to 20 cmH2O
-
Flow Trigger Sensitivity (FTr) : 0.5 L/min to 30 L/min
-
SIGH : 0 (off) 1/100 to 5/100
-
Apnea Ventilation : OFF, 5 s to 60 s
-
Gas Pressure Range : 280 kPa to 600 kPa
-
Pressure Limit : 20 cmH2O to 100 cmH2O
-
Bellow : 1.5L
-
Oscillogram Types : P-T (Pressure-Time),
F-T (Flow-Time),
P-V loop (Pressure-Volume Loop)
-
AC Power Failure Alarm : Yes
-
Battery Backup Low Voltage Alarm : Yes; threshold < 11.3 ± 0.3 V
-
Tidal Volume Alarm : Triggered if no tidal volume is detected
-
High/Low Oxygen Concentration Alarm : 19 % to 100 % (High);
18 % to 99 % (Low)
-
Airway Pressure Alarms : High: 20 cmH2O to 100 cmH2O;
Low: 0 cmH2O to 20 cmH2O
-
Minute Volume Alarms : Adult: 5 L/min to 20 L/min;
Pediatric: 1 L/min to 15 L/min
-
Continuous Pressure Alarm : Over (PEEP + 1.5 kPa) for 16 s
-
Suffocation Warning : 5 s to 60 s with no spontaneous ventilation
-
Maximum Limited Pressure : ≤12.5 kPa
-
Fan Error, Oxygen Deficit, Power Failure : Displayed on screen
-
Display : 10.4"Colorful TFT LCD
-
Power Consumption : 80VA
-
Power Supply : Voltage: 100 to 240 V
Power Frequency: 50/60 Hz
-
Packing Dimension : 920 × 970 × 1390 mm
-
Net Weight : 87.5 kg
-
Gross Weight : 155 kg
Anesthesia System MD-ANS-1003
-
Ventilation Modes : IPPV, PCV, A/C, SIMV, SIGH, MANUAL
-
Gas Source : O2, N2O
-
Flowmeter range : O22: 0 to 10 L/min;
N2O: 0 to 10 L/min
-
Rapid Oxygen Supply Range : 25 L/min to 75 L/min
-
Oxygen Concentration : 15 % to 100 %
-
Tidal Volume (Vt) range : 0, 20 mL to 1500 mL
-
Frequency range : 1 /min to 100 /min
-
Inspiratory Ratio (I) : 0.2s to 6s 2:1 - 1:6
-
Minute Volume (MV) : 0 L/min to 100 L/min
-
Positive End-Expiratory Pressure (PEEP) : 0 cmH2O to 30 cmH2O
-
Pressure Triggering Sensitivity (PTr) : -20 cmH2O to 20 cmH2O
-
Flow Trigger Sensitivity (FTr) : 0.5 L/min to 30 L/min
-
SIGH : 0 (off) 1/100 to 5/100
-
Apnea Ventilation : OFF, 5 s to 60 s
-
Gas Pressure Range : 280 kPa to 600 kPa
-
Pressure Limit : 20 cmH,sub>2O to 100 cmH2O
-
Oscillogram Types : P-T (Pressure-Time),
F-T (Flow-Time),
V-T (Volume-Time)
P-V loop (Pressure-Volume Loop)
F-V (Flow-Volume Loop)
F-P (Flow-Pressure Loop)
ETCO2-T (ETCO2-Time)
-
The AC power failure alarm : Power failure or no connection
-
Low voltage alarm for backup battery : < 11.3 ± 0.3 V
-
No tidal volume : ≤ 5 mL within 6 s
-
High oxygen concentration alarm : 19% to 100%
-
Low oxygen concentration alarm : 18% to 99%
-
High airway pressure alarm : 20 cmH2O to 100 cmH2O
-
Low airway pressure alarm : 0 cmH2O to 20 cmH2O
-
High-minute volume alarm : Adult (5 L/min to 20 L/min)
-
Low-minute volume alarm : Paed (1 L/min to 15 L/min, 0 ~ 10 L/min)
-
Continuous pressure alarm : (PEEP+1.5 kPa) over 16s
-
Suffocation warning : 5s-60s no spontaneous ventilation
-
The maximum limited pressure : ≤ 12.5 kPa
-
Fan error : Show on screen
-
Oxygen deficit : Show on screen
-
Power Consumption : 85 VA
-
Power Supply : Voltage: 100 to 240 V
Power Frequency: 50/60 Hz
-
Packing Dimension : 740 × 795 × 1540 mm
-
Net Weight : 52.5 kg
-
Gross Weight : 119 kg
Anesthesia System MD-ANS-1004
-
Ventilation Modes : IPPV, PCV, A/C, P-SIMV, V-SIMV, PSV, PCV-VG SIGH, MANUAL
-
Gas Source : O2, N2O
-
Flowmeter range : O2: 0 to 10 L/min;
N2O: 0 to 10 L/min
-
Rapid Oxygen Supply Range : 25 L/min to 75 L/min
-
Oxygen Concentration : 15 % to 100 %
-
Tidal Volume (Vt) range : 0, 20 mL to 1500 mL
-
Frequency range : 1 /min to 100 /min
-
Inspiratory Ratio (I) : 2:1 to 1:6
-
Inspirational time : 0.2s to 6s
-
Minute Volume (MV) : 0 L/min to 100 L/min
-
Positive End-Expiratory Pressure (PEEP) : 0 cmH2O to 30 cmH2O
-
Pressure Triggering Sensitivity (PTr) : -20 cmH2O to 20 cmH2O
-
Flow Trigger Sensitivity (FTr) : 0.5 L/min to 30 L/min
-
SIGH : 0 (off) 1/100 to 5/100
-
Apnea Ventilation : OFF, 5 s to 60 s
-
Gas Pressure Range : 280 kPa to 600 kPa
-
Pressure Limit : 20 cmH2O to 100 cmH2O
-
Bellow : 1.5L
-
Oscillogram Types : P-T (Pressure-Time),
F-T (Flow-Time),
V-T (Volume-Time)
P-V loop (Pressure-Volume Loop)
F-V (Flow-Volume Loop)
F-P (Flow-Pressure Loop)
ETCO2-T (ETCO2-Time)
-
The AC power failure alarm : Power failure or no connection
-
Low voltage alarm for backup battery : < 10.2 ± 0.3 V
-
No tidal volume : ≤ 5 mL within 6 s
-
High oxygen concentration alarm : 19% to 100%
-
Low oxygen concentration alarm : 18% to 99%
-
High airway pressure alarm : 20 cmH2O to 100 cmH2O
-
Low airway pressure alarm : 0 cmH2O to 20 cmH2O
-
High-minute volume alarm : Adult (5 L/min to 20 L/min)
-
Low-minute volume alarm : Paed (1 L/min to 15 L/min, 0 to 10 L/min)
-
Continuous pressure alarm : (PEEP+1.5 kPa) over 16s
-
Suffocation warning : 5s-60s no spontaneous ventilation
-
The maximum limited pressure : ≤ 12.5 kPa
-
Fan error : Show on screen
-
Oxygen deficit : Show on screen
-
Display : 10.4"Colorful TFT LCD
-
Power Consumption : 85 VA
-
Power Supply : Voltage: 100 to 240 V
Power Frequency: 50/60 Hz
-
Packing Dimension : 920 × 970 × 1380 mm
-
Net Weight : 87.5 kg
-
Gross Weight : 155 kg
Anesthesia System MD-ANS-1005
-
Ventilation Modes : IPPV, PCV, A/C, SIMV, SIGH, MANUAL
-
Gas Source : O2, N2O, AIR
-
Flowmeter range : O2: 0 to 10 L/min
N2O: 0 to 10 L/min
-
Rapid Oxygen Supply Range : 25 L/min to 75 L/min
-
Oxygen Concentration Range : 15 % to 100 %
-
Inspiratory Ratio (I) : VTH 4:1 to 1:8 VTL 2:1 to 1:8
-
Tidal Volume Range : 0, 20 mL to 1500 mL
-
Minute Volume : ≥18 L/min
-
Frequency range : 1 breath /min to 100 breath /min
-
Positive End-Expiratory Pressure (PEEP) : 0 cmH2O to 30 cmH2O
-
Pressure control (PC) : 5 cmH2O to 60 cmH2O
-
Pressure Triggering Sensitivity (PTr) : -20 cmH2O to 0 cmH2O
-
Flow Trigger Sensitivity (FTr) : 0.5 L/min to 30 L/min
-
Apnea Ventilation : OFF, 5 s to 60 s
-
SIGH : 0 (off) 1/100 to 5/100
-
Gas Pressure Range : 280 kPa to 600 kPa
-
Pressure Limit : 20 cmH2O to 100 cmH2O
-
Bellow : 1.5L
-
Oscillogram Types : P-T (Pressure-Time)
F-T (Flow-Time)
V-T (Volume-Time)
P-V loop (Pressure-Volume Loop)
F-V (Flow-Volume Loop)
P - F (Pressure - Flow Loop)
ETCO2-T (ETCO2-Time)
-
The AC power failure alarm : Power failure or no connection
-
Low voltage alarm for backup battery : < 10.2 ± 0.3 V
-
No tidal volume : ≤ 5 mL within 6 s
-
High oxygen concentration alarm Range : 19% to 100%
-
Low oxygen concentration alarm Range : 18% to 99%
-
High airway pressure alarm Range : 20 cmH2O to 100 cmH2O
-
Low airway pressure alarm Range : 0 cmH2O to 20 cmH2O
-
High-minute volume alarm Range : Adult (5 L/min to 20 L/min)
-
Low-minute volume alarm Range : Paed (1 L/min to 15 L/min, 0 to 10 L/min)
-
Continuous pressure alarm Range : (PEEP+1.5 kPa) over 16s
-
Suffocation warning : 5s to 60s no spontaneous ventilation
-
The maximum limited pressure : ≤ 12.5 kPa
-
Fan error : Display on screen
-
Oxygen deficit : Display on screen
-
Display : 12.1" TFT LCD touchscreen
-
Power Consumption : 85 VA
-
Power Supply : Voltage: 100 to 240 V Power Frequency: 50/60 Hz
-
Packing Dimension : 1005 × 960 × 1700 mm
-
Net Weight : 116.5 kg
-
Gross Weight : 227 kg
Anesthesia System MD-ANS-1006
-
Ventilation Modes : IPPV, PCV-PC, PCV-VG, V-A/C, P-A/C, P-SIMV, V-SIMV, PSV, PCV-VG SIGH, MANUAL
-
Gas source : O2, N2O, AIR
-
Flowmeter Range : O2: 0.2 to 15 L/min
N2O: 0.2 to 12 L/min
AIR: 0.2 to 15 L/min
-
Rapid Oxygen Supply : 25 L/min to 75 L/min
-
Oxygen Concentration Range : 15 % to 100 %
-
Inspiratory Ratio (I) : 4:1 to 1:8
-
Tidal Volume (Vt) range : 0, 10 mL to 1500 mL
-
Minute Volume (MV) Range : 0 L/min to 100 L/min
-
Frequency Range : 0 /min to 120 /min
-
Positive End-Expiratory Pressure (PEEP) : 0 cmH2O to 30 cmH2O
-
Pressure Control Range : 5 cmH2O to 70 cmH2O
-
Pressure Triggering Sensitivity (PTr) : -20 cmH2O to 0 cmH2O
-
Flow Trigger Sensitivity (FTr) : OFF, 0.5 L/min to 30 L/min
-
Apnea Ventilation : OFF, 5% to 60%
-
SIGH : 0 (off) 1/100 to 5/100
-
Gas Pressure Range : 280 kPa to 600 kPa
-
Pressure Limit : 10 cmH2O to 100 cmH2O
-
Bellow : 1L
-
Oscillogram Types : P-T (Pressure-Time)
F-T (Flow-Time),
V-T (Volume-Time)
P-V loop (Pressure-Volume Loop)
ETCO2-T (ETCO2-Time)
F-V (Flow-Volume Loop)
F-P (Flow-Pressure Loop)
-
High-minute volume alarm : Power supply Undervoltage alarm
-
Low-minute volume alarm : Low tidal volume alarm
-
High airway pressure alarm : Continuous pressure alarm
-
Low airway pressure alarm : High-frequency alarm
-
No tidal volume : Suffocation alarm
-
High tidal volume alarm : Backup power alarm
-
Absorber disconnection alarm : Battery exhausted alarm
-
High oxygen concentration alarm : Fan error
-
Low oxygen concentration alarm : Low oxygen supply alarm
-
High ETCO2 concentration alarm : Low oxygen supply alarm
-
Power Consumption : 85 VA
-
Power Supply : Voltage: 100 to 240 V Power Frequency: 50/60 Hz
-
Packing Dimension : 1005 × 960 × 1700 mm
-
Net Weight : 126 kg
-
Gross Weight : 253 kg
Anesthesia System MD-ANS-1007 MD-ANS-1007
-
Ventilation Modes : IPPV, PCV-PC, PCV-VG, V-A/C, P-A/C, P-SIMV, V-SIMV, PSV, PCV-VG SIGH, MANUAL
-
Gas Source : O2, N2O, AIR
-
Flowmeter range : O2: 0 to 15 L/min
N2O: 0 to 12 L/min
AIR: 0 to 15 L/min
-
Rapid Oxygen Supply Range : 35 L/min to 75 L/min
-
Oxygen Concentration : 15 % to 100 %
-
Tidal Volume (Vt) range : 0, 10 mL to 1500 mL
-
Frequency range : 4 /min to 100 /min
-
Inspiratory Ratio (I) : 4:1 to 1:10
-
Inspiration Time Range : 0.2 s to 5 s
-
Minute Volume (MV) Range : 0 L/min to 100 L/min
-
Positive End-Expiratory Pressure (PEEP) : 0 cmH2O to 30 cmH2O
-
Pressure Triggering Sensitivity (PTr) : -20 cmH2O to 0 cmH2O
-
Flow Trigger Sensitivity (FTr) : 0.3 L/min to 15 L/min
-
Gas Pressure Range : 280 kPa to 600 kPa
-
Pressure Limit : 10 cmH2O to 100 cmH2O
-
SIGH : 0 (off) 1/100 to 5/100
-
Inspiration Apnea Ventilation : OFF, 5% to 60%
-
Trigger : 5% to 95%
-
SIMV frequency range : 4 /min to 60 /min
-
Rise time : 0 s to 2 s
-
Bellow : 1L
-
Oscillogram Types : P-T (Pressure-Time)
F-T (Flow-Time),
V-T (Volume-Time)
P-V loop (Pressure-Volume Loop)
ETCO2-T (ETCO2-Time)
F-V (Flow-Volume Loop)
F-P (Flow-Pressure Loop)
-
High-minute volume alarm : Power supply Undervoltage alarm
-
Low-minute volume alarm : Low tidal volume alarm
-
High airway pressure alarm : Continuous pressure alarm
-
Low airway pressure alarm : High-frequency alarm
-
No tidal volume : Suffocation alarm
-
High tidal volume alarm : Backup power alarm
-
Absorber disconnection alarm : Battery exhausted alarm
-
High oxygen concentration alarm : Fan error
-
Low oxygen concentration alarm : Low oxygen supply alarm
-
High ETCO2 concentration alarm : Low-frequency alarm
-
Power Consumption : 85 VA
-
Power Supply : Voltage: 100 to 240 V Power Frequency: 50/60 Hz
-
Packaging Dimension : 1005 × 960 × 1700 mm
-
Net Weight : 132 kg
-
Gross Weight : 253 kg