• Anesthesia System MD-ANS-1004
  • Anesthesia System MD-ANS-1004
  • Anesthesia System MD-ANS-1004
Anesthesia System MD-ANS-1004

Anesthesia System MD-ANS-1004

$11,100

Anesthesia System MD-ANS-1004 equipped with flowmeters for O2, N2O, and AIR, adjustable from 0.1 to 10 L/min. The Real-time monitoring of respiratory parameters with oscillograms and loops supports precise monitoring. It offers ventilation capabilities tailored for both adult and pediatric patients. It combines technology with a user-friendly interface, ensuring safety and efficiency in critical care settings. Our system offers comprehensive monitoring and ventilation capabilities, ensuring Safety and precision.

Ventilation Modes IPPV, PCV, A/C, P-SIMV, V-SIMV, PSV, PCV-VG SIGH, MANUAL
Gas Source O2, N2O
Flowmeter range O2: 0 to 10 L/min;
N2O: 0 to 10 L/min
Rapid Oxygen Supply Range 25 L/min to 75 L/min
Oxygen Concentration 15 % to 100 %
Tidal Volume (Vt) range 0, 20 mL to 1500 mL
Frequency range 1 /min to 100 /min
Inspiratory Ratio (I) 2:1 to 1:6
Inspirational time 0.2s to 6s
Minute Volume (MV) 0 L/min to 100 L/min
Positive End-Expiratory Pressure (PEEP) 0 cmH2O to 30 cmH2O
Pressure Triggering Sensitivity (PTr) -20 cmH2O to 20 cmH2O
Flow Trigger Sensitivity (FTr) 0.5 L/min to 30 L/min
SIGH 0 (off) 1/100 to 5/100
Apnea Ventilation OFF, 5 s to 60 s
Gas Pressure Range 280 kPa to 600 kPa
Pressure Limit 20 cmH2O to 100 cmH2O
Bellow 1.5L
Oscillogram Types P-T (Pressure-Time),
F-T (Flow-Time),
V-T (Volume-Time)
P-V loop (Pressure-Volume Loop)
F-V (Flow-Volume Loop)
F-P (Flow-Pressure Loop)
ETCO2-T (ETCO2-Time)
The AC power failure alarm Power failure or no connection
Low voltage alarm for backup battery < 10.2 ± 0.3 V
No tidal volume ≤ 5 mL within 6 s
High oxygen concentration alarm 19% to 100%
Low oxygen concentration alarm 18% to 99%
High airway pressure alarm 20 cmH2O to 100 cmH2O
Low airway pressure alarm 0 cmH2O to 20 cmH2O
High-minute volume alarm Adult (5 L/min to 20 L/min)
Low-minute volume alarm Paed (1 L/min to 15 L/min, 0 to 10 L/min)
Continuous pressure alarm (PEEP+1.5 kPa) over 16s
Suffocation warning 5s-60s no spontaneous ventilation
The maximum limited pressure ≤ 12.5 kPa
Fan error Show on screen
Oxygen deficit Show on screen
Display 10.4"Colorful TFT LCD
Power Consumption 85 VA
Power Supply Voltage: 100 to 240 V
Power Frequency: 50/60 Hz
Packing Dimension 920 × 970 × 1380 mm
Net Weight 87.5 kg
Gross Weight 155 kg
    • Multiple Ventilation Modes

    • Equipped with flowmeters 

    • 10.4"Colorful TFT LCD

    • Real-time monitoring 

    • User-Friendly Interface

    • AC power failure alarm

    • high/low-pressure limits

    • built-in protections 

    • Built-in Battery Backup

    • Compact and Light-weight

    • Anesthetic breathing system × 1

    • Power cord 4m × 1

    • Fuse 50V × 2

    • Fuse × 1

    • O2cell × 1

    • Adult Anesthesia Breathing Circuit(reusable) × 2

    • Child Anesthesia Breathing Circuit(reusable) × 2

    • Breathing tube × 1

    • Y connector × 1

    • Y connector × 1

    • L connector × 1

    • Straight connector × 1

    • Reservoir bag 1L × 1

    • Reservoir bag 3L × 1

    • Anesthetic mask adult × 1

    • Anesthetic mask infant × 1

    • Vaporizer × 2

    • High pressure O2 hose 4.472.018,4 m × 1

    • High-pressure AIR hose 4.472.026,4 m × 1

    • CO2 sensor × 1

    • Spare Cylinder yoke, 1 O2, includes gauges × 1

    • Spare Cylinder yoke, 1 N2O, includes gauges × 1

    • Disposable Adult breathing circuit × 1

    • Disposable Pediatric breathing circuit × 1

    • Transfer and receiving system of exhaust gas × 1

    • Patient monitor × 1

  • Anesthesia System MD-ANS-1004 is a comfortable and classic choice, and is user-friendly, with its outstanding ergonomic design, this machine prioritizes safety, stability, and convenience, ensuring an enhanced user experience. 