$11,100
Anesthesia System MD-ANS-1004 equipped with flowmeters for O2, N2O, and AIR, adjustable from 0.1 to 10 L/min. The Real-time monitoring of respiratory parameters with oscillograms and loops supports precise monitoring. It offers ventilation capabilities tailored for both adult and pediatric patients. It combines technology with a user-friendly interface, ensuring safety and efficiency in critical care settings. Our system offers comprehensive monitoring and ventilation capabilities, ensuring Safety and precision.
Ventilation Modes | IPPV, PCV, A/C, P-SIMV, V-SIMV, PSV, PCV-VG SIGH, MANUAL |
Gas Source | O<sub>2</sub>, N<sub>2</sub>O |
Flowmeter range | O<sub>2</sub>: 0 to 10 L/min;<br> N<sub>2</sub>O: 0 to 10 L/min |
Rapid Oxygen Supply Range | 25 L/min to 75 L/min |
Oxygen Concentration | 15 % to 100 % |
Tidal Volume (Vt) range | 0, 20 mL to 1500 mL |
Frequency range | 1 /min to 100 /min |
Inspiratory Ratio (I) | 2:1 to 1:6 |
Inspirational time | 0.2s to 6s |
Minute Volume (MV) | 0 L/min to 100 L/min |
Positive End-Expiratory Pressure (PEEP) | 0 cmH<sub>2</sub>O to 30 cmH<sub>2</sub>O |
Pressure Triggering Sensitivity (PTr) | -20 cmH<sub>2</sub>O to 20 cmH<sub>2</sub>O |
Flow Trigger Sensitivity (FTr) | 0.5 L/min to 30 L/min |
SIGH | 0 (off) 1/100 to 5/100 |
Apnea Ventilation | OFF, 5 s to 60 s |
Gas Pressure Range | 280 kPa to 600 kPa |
Pressure Limit | 20 cmH<sub>2</sub>O to 100 cmH<sub>2</sub>O |
Bellow | 1.5L |
Oscillogram Types | P-T (Pressure-Time),<br> F-T (Flow-Time),<br> V-T (Volume-Time)<br> P-V loop (Pressure-Volume Loop)<br> F-V (Flow-Volume Loop)<br> F-P (Flow-Pressure Loop)<br> ETCO<sub>2</sub>-T (ETCO<sub>2</sub>-Time) |
The AC power failure alarm | Power failure or no connection |
Low voltage alarm for backup battery | < 10.2 ± 0.3 V |
No tidal volume | ≤ 5 mL within 6 s |
High oxygen concentration alarm | 19% to 100% |
Low oxygen concentration alarm | 18% to 99% |
High airway pressure alarm | 20 cmH<sub>2</sub>O to 100 cmH<sub>2</sub>O |
Low airway pressure alarm | 0 cmH<sub>2</sub>O to 20 cmH<sub>2</sub>O |
High-minute volume alarm | Adult (5 L/min to 20 L/min) |
Low-minute volume alarm | Paed (1 L/min to 15 L/min, 0 to 10 L/min) |
Continuous pressure alarm | (PEEP+1.5 kPa) over 16s |
Suffocation warning | 5s-60s no spontaneous ventilation |
The maximum limited pressure | ≤ 12.5 kPa |
Fan error | Show on screen |
Oxygen deficit | Show on screen |
Display | 10.4"Colorful TFT LCD |
Power Consumption | 85 VA |
Power Supply | Voltage: 100 to 240 V<br> Power Frequency: 50/60 Hz |
Packing Dimension | 920 × 970 × 1380 mm |
Net Weight | 87.5 kg |
Gross Weight | 155 kg |
Multiple Ventilation Modes
Equipped with flowmeters
10.4"Colorful TFT LCD
Real-time monitoring
User-Friendly Interface
AC power failure alarm
high/low-pressure limits
built-in protections
Built-in Battery Backup
Compact and Light-weight
Anesthetic breathing system × 1
Power cord 4m × 1
Fuse 50V × 2
Fuse × 1
O2cell × 1
Adult Anesthesia Breathing Circuit(reusable) × 2
Child Anesthesia Breathing Circuit(reusable) × 2
Breathing tube × 1
Y connector × 1
Y connector × 1
L connector × 1
Straight connector × 1
Reservoir bag 1L × 1
Reservoir bag 3L × 1
Anesthetic mask adult × 1
Anesthetic mask infant × 1
Vaporizer × 2
High pressure O2 hose 4.472.018,4 m × 1
High-pressure AIR hose 4.472.026,4 m × 1
CO2 sensor × 1
Spare Cylinder yoke, 1 O2, includes gauges × 1
Spare Cylinder yoke, 1 N2O, includes gauges × 1
Disposable Adult breathing circuit × 1
Disposable Pediatric breathing circuit × 1
Transfer and receiving system of exhaust gas × 1
Patient monitor × 1
Anesthesia System MD-ANS-1004 is a comfortable and classic choice, and is user-friendly, with its outstanding ergonomic design, this machine prioritizes safety, stability, and convenience, ensuring an enhanced user experience.
Anesthesia System deliver a precise mixture of gases and agents to the patient through a breathing circuit. The ventilator helps control respiration, and monitoring devices track vital signs during the procedure.
Vaporizers convert liquid anesthetic agents into vapours and precisely mix them with carrier gases (like oxygen or air) for patient administration.
Common problems include leaks in the breathing circuit, malfunctions in the vaporizers, and issues with the ventilator.
Anesthesia technicians and engineers are trained to diagnose and repair problems with these machines.
The pipeline pressure is 50-55 PSI. It is kept slightly higher than the cylinder pressure to ensure a continuous supply of gases. 10.
Vaporizers deliver a controlled amount of anesthetic liquid into the gas stream, allowing for precise administration of the anesthetic agent.
Fresh gas flow refers to the continuous supply of gases and anesthetic agents delivered to the patient through the breathing circuit.
Vaporizers convert liquid anesthetic agents into vapours and precisely mix them with carrier gases (like oxygen or air) for patient administration.