Anesthesia System MD-ANS-1004

Anesthesia System MD-ANS-1004

$11,100

Anesthesia System MD-ANS-1004 equipped with flowmeters for O2, N2O, and AIR, adjustable from 0.1 to 10 L/min. The Real-time monitoring of respiratory parameters with oscillograms and loops supports precise monitoring. It offers ventilation capabilities tailored for both adult and pediatric patients. It combines technology with a user-friendly interface, ensuring safety and efficiency in critical care settings. Our system offers comprehensive monitoring and ventilation capabilities, ensuring Safety and precision.

Ventilation Modes IPPV, PCV, A/C, P-SIMV, V-SIMV, PSV, PCV-VG SIGH, MANUAL
Gas Source O<sub>2</sub>, N<sub>2</sub>O
Flowmeter range O<sub>2</sub>: 0 to 10 L/min;<br> N<sub>2</sub>O: 0 to 10 L/min
Rapid Oxygen Supply Range 25 L/min to 75 L/min
Oxygen Concentration 15 % to 100 %
Tidal Volume (Vt) range 0, 20 mL to 1500 mL
Frequency range 1 /min to 100 /min
Inspiratory Ratio (I) 2:1 to 1:6
Inspirational time 0.2s to 6s
Minute Volume (MV) 0 L/min to 100 L/min
Positive End-Expiratory Pressure (PEEP) 0 cmH<sub>2</sub>O to 30 cmH<sub>2</sub>O
Pressure Triggering Sensitivity (PTr) -20 cmH<sub>2</sub>O to 20 cmH<sub>2</sub>O
Flow Trigger Sensitivity (FTr) 0.5 L/min to 30 L/min
SIGH 0 (off) 1/100 to 5/100
Apnea Ventilation OFF, 5 s to 60 s
Gas Pressure Range 280 kPa to 600 kPa
Pressure Limit 20 cmH<sub>2</sub>O to 100 cmH<sub>2</sub>O
Bellow 1.5L
Oscillogram Types P-T (Pressure-Time),<br> F-T (Flow-Time),<br> V-T (Volume-Time)<br> P-V loop (Pressure-Volume Loop)<br> F-V (Flow-Volume Loop)<br> F-P (Flow-Pressure Loop)<br> ETCO<sub>2</sub>-T (ETCO<sub>2</sub>-Time)
The AC power failure alarm Power failure or no connection
Low voltage alarm for backup battery < 10.2 ± 0.3 V
No tidal volume ≤ 5 mL within 6 s
High oxygen concentration alarm 19% to 100%
Low oxygen concentration alarm 18% to 99%
High airway pressure alarm 20 cmH<sub>2</sub>O to 100 cmH<sub>2</sub>O
Low airway pressure alarm 0 cmH<sub>2</sub>O to 20 cmH<sub>2</sub>O
High-minute volume alarm Adult (5 L/min to 20 L/min)
Low-minute volume alarm Paed (1 L/min to 15 L/min, 0 to 10 L/min)
Continuous pressure alarm (PEEP+1.5 kPa) over 16s
Suffocation warning 5s-60s no spontaneous ventilation
The maximum limited pressure ≤ 12.5 kPa
Fan error Show on screen
Oxygen deficit Show on screen
Display 10.4"Colorful TFT LCD
Power Consumption 85 VA
Power Supply Voltage: 100 to 240 V<br> Power Frequency: 50/60 Hz
Packing Dimension 920 × 970 × 1380 mm
Net Weight 87.5 kg
Gross Weight 155 kg
    • Multiple Ventilation Modes

    • Equipped with flowmeters 

    • 10.4"Colorful TFT LCD

    • Real-time monitoring 

    • User-Friendly Interface

    • AC power failure alarm

    • high/low-pressure limits

    • built-in protections 

    • Built-in Battery Backup

    • Compact and Light-weight

    • Anesthetic breathing system × 1

    • Power cord 4m × 1

    • Fuse 50V × 2

    • Fuse × 1

    • O2cell × 1

    • Adult Anesthesia Breathing Circuit(reusable) × 2

    • Child Anesthesia Breathing Circuit(reusable) × 2

    • Breathing tube × 1

    • Y connector × 1

    • Y connector × 1

    • L connector × 1

    • Straight connector × 1

    • Reservoir bag 1L × 1

    • Reservoir bag 3L × 1

    • Anesthetic mask adult × 1

    • Anesthetic mask infant × 1

    • Vaporizer × 2

    • High pressure O2 hose 4.472.018,4 m × 1

    • High-pressure AIR hose 4.472.026,4 m × 1

    • CO2 sensor × 1

    • Spare Cylinder yoke, 1 O2, includes gauges × 1

    • Spare Cylinder yoke, 1 N2O, includes gauges × 1

    • Disposable Adult breathing circuit × 1

    • Disposable Pediatric breathing circuit × 1

    • Transfer and receiving system of exhaust gas × 1

    • Patient monitor × 1

  • Anesthesia System MD-ANS-1004 is a comfortable and classic choice, and is user-friendly, with its outstanding ergonomic design, this machine prioritizes safety, stability, and convenience, ensuring an enhanced user experience. 

Ask Our Experts
Captcha Image

Anesthesia System

Frequently Asked Questions

How does an anesthesia system work?

Anesthesia System deliver a precise mixture of gases and agents to the patient through a breathing circuit. The ventilator helps control respiration, and monitoring devices track vital signs during the procedure.

What is the purpose of a vaporizer in an anesthesia system?

Vaporizers convert liquid anesthetic agents into vapours and precisely mix them with carrier gases (like oxygen or air) for patient administration.

What are some common problems that can occur with anesthesia system?

Common problems include leaks in the breathing circuit, malfunctions in the vaporizers, and issues with the ventilator.

How are problems with anesthesia system diagnosed and repaired?

Anesthesia technicians and engineers are trained to diagnose and repair problems with these machines.

What is the pipeline pressure in an anesthesia system?

The pipeline pressure is 50-55 PSI. It is kept slightly higher than the cylinder pressure to ensure a continuous supply of gases. 10.

What is the purpose of a vaporizer on an anesthesia system?

Vaporizers deliver a controlled amount of anesthetic liquid into the gas stream, allowing for precise administration of the anesthetic agent.

What is fresh gas flow in an anesthesia system

Fresh gas flow refers to the continuous supply of gases and anesthetic agents delivered to the patient through the breathing circuit.

What is the purpose of a vaporizer in an anesthesia system?

Vaporizers convert liquid anesthetic agents into vapours and precisely mix them with carrier gases (like oxygen or air) for patient administration.

>